Esta tecnología permite el análisis de la cinemática de los movimientos corporales y registra datos e imágenes en tres dimensiones (3D), para permitir en análisis y la valoración del movimiento en los planos frontal, sagital y trasversal. That, the proposed classification method based in Jacobi Fourier momentsĬan be well addressed to grade images smeared by motion.El presente trabajo muestra las perspectivas de aplicación y uso de la tecnología de análisis de movimiento para el diagnóstico y seguimiento en procesos terapéuticos, mediante el análisis de parámetros de movimiento, apoyado en la tecnología de BTS SMART-E. Intrinsically little differences between them. TheĬlassification method is tested using images from objects which have The geometric moments of motion function of the object centroid. Also, the acquisition system is characterizedīy means the optical transfer function (OTF) which can be computed by The blur extent by image motion can be obtained using momentĭescriptors of the motion. Objects are vibrating at different frequencies and moving at constant The test images used here have been acquired when the The scale, orientation, position, and illumination of the objects in the These features are invariant to the changes in A set of numerical features areĮxtracted from an image. We consider the use of Jacobi-Fourier moments for the classification of El sistema desarrollado corresponde a un sistema electromecánico que permite desplazar una plataforma con cámara a lo largo de un par de barras paralelas, de baja incertidumbre con la posibilidad de medir la velocidad y aceleración instantáneas para el estudio de imágenes reales con difuminadas por movimiento uniforme y la enseñanza de física básica. El desarrollo del sistema se dividió en los siguientes pasos: diseño electromecánico para velocidad, calibración de la velocidad, diseño electromecánico para aceleración y calibración de la aceleración.Se obtuvieron incertidumbres máximas de 0,031 □/□ para la velocidad y de 0,029 □/□2 para la aceleración del sistema. En este artículo se presenta el diseño, construcción y calibración de un sistema electromecánico para el estudio de las imágenes con difuminación uniforme. Seguido, el sistema fue calibrado con respecto a un instrumento patrón para el cálculo de incertidumbres y error. Se presentan los requerimientos de diseño mecánico y eléctrico basados en las condiciones de presentación del fenómeno. Method:The development of the system is split into the following steps: the design and construction of an aluminum electromechanical slider built with a mobile platform that moves at constant speed, the calibration of the speed of the mobile platform using the Guide to Estimate Uncertainty in the Measurement, the design and construction of the electromechanical aluminum slider mounted with a mobile platform atconstant acceleration and the calibration of the mobile platform for the acceleration applying the Guide for Estimation of Measurement Uncertainty.Results:Maximum uncertainties of 0,031푚/푠were obtained for speed and 0,029푚/푠2for acceleration of the system.Conclusions:The developed system corresponds to an electromechanical system that allows to move a cart along a pair of parallel bars, of low uncertainty with the possibility of measuring instantaneous speed and acceleration for the study of motion blurredimagesand teaching of motion physicsĮn este artículo se presenta el diseño y la construcción de un riel electromecánico que permite obtener la velocidad y aceleración instantáneas de una plataforma que soporta una cámara científica al momento de la captura de la imagen, para el estudio de las imágenes difuminadas por movimiento uniforme (Motion blur). The system was calibrated concerning a standard instrumentfor the estimation of the uncertainty and error.Objective: the design, the making, and the calibration of an electromechanical slider system for the study of motion-blurred images.Objective:In this paper, the design, constructionand calibrationof an electromechanical system for the study of images with uniformmotion blur ispresented. The mechanical and electrical design requirements are given based on the conditions of presentation of the phenomenon. Ntroduction: This paper introduces the design and the construction of an electromechanical slider that allows obtaining the instantaneous speed and acceleration of a platform thatholds a scientific camera to take photos for the study motion-blurred images.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |